Saltar al contenido principal

Integración domótica Recalls US, gratuita y de código abierto

Integración Recalls US para Gladys Assistant

Recalls in the United States: consumer products, food, drugs and your vehicles.

info

La documentación de esta integración la escribe su autor y, por ahora, solo está disponible en inglés.

Recalls published in the United States, read from the public data of three agencies: consumer products of the Consumer Product Safety Commission (CPSC), food, drugs and medical devices of the Food and Drug Administration (openFDA enforcement reports), and the recall campaigns of your vehicles at the National Highway Traffic Safety Administration (NHTSA), by make, model and model year, or by VIN. The integration gives Gladys a device with three values, a scene trigger for each new recall of your selection, a scene action and a dashboard widget.

It was tested against the real services (30/10/2026) and on fake servers built from their answers, not yet over weeks of real use nor with a real Gladys. No device of yours is involved: the data comes from the cloud.

What you get​

  • A device Recalls in the United States with:
    • Recalls in 7 days: the recalls of your selection whose day is one of the last 7 days (today included, in the time zone of Gladys): the recall date of CPSC, the report date of the FDA (a Wednesday, once a week), the day NHTSA received the report of a vehicle campaign.
    • Vehicle recall campaigns: the campaigns NHTSA lists for your vehicles, all years together. No value when no vehicle is followed.
    • Latest recall: the newest recall of the 7 days, with its day.
  • A scene trigger United States: new recall in my selection, with the title, product, firm, category, reason, remedy, FDA class, vehicle, day, link and a one-sentence summary as variables. The trigger can be limited to some categories (vehicles included).
  • A scene action United States: read the recalls of the last 7 days (a sentence to send by message or read aloud, the count of the 7 days, and the count of the vehicle campaigns, absent when no vehicle is followed).
  • A widget Recalls in the United States: the recalls of the 7 days, then the latest campaigns of your vehicles, the most serious in red (FDA Class I, or a vehicle NHTSA advises not to drive or to park outside), with links.
  • A button Show the recalls of the last 7 days in the configuration.

Configuration​

  1. Categories: consumer products (CPSC), food (FDA), drugs (FDA), medical devices (FDA). Medical devices are not followed by default: about 250 a month, nearly all hospital equipment.
  2. Brands or words (optional): only the CPSC and FDA recalls naming one of them in their title, product or firm, separated by commas. Accents and case do not matter; a word matches whole words only ("nut" does not match "peanut"). Vehicles are not filtered.
  3. Vehicles (optional): make, model, year for each vehicle, separated by semicolons, e.g. Honda, Civic, 2019; Ford, F-150, 2021, spelled as NHTSA spells them (nhtsa.gov/recalls lists them). A vehicle NHTSA does not know has no campaign: the status then asks to check the spelling.
  4. VINs (optional): up to 3 VINs (17 characters), separated by commas, instead of typing the vehicles. Five vehicles in all.
  5. Check interval: 3, 6 (default), 12 or 24 hours.
  6. Language of the texts: English or French: the names of the features at their creation and the texts sent to the scenes. The recalls themselves are published in English by the agencies.

Save, then create the device in the Discover tab.

Your VINs​

A VIN is a field of type secret: kept by Gladys in its database, never shown again, sent only to NHTSA (vPIC, vpic.nhtsa.dot.gov) to learn the make, model and model year. The integration never writes it in its logs (debug included), its status, its memory (/data), the scene events, the widget or the actions: they say "VIN 2" and the make, model and year. /data keeps the campaigns under the make, model and year, as for a typed vehicle.

A VIN is decoded when it is saved, at each start, and again once a day. A start less than 10 minutes after a decoding (a container restarting in a loop) does not ask vPIC again: it takes the make, model and year decoded then, kept by position in /data (never the VIN), until the 10 minutes are over. A VIN changed while the integration was stopped is thus followed at most 10 minutes late. The recalls are then those of the make, model and year, not of your very vehicle: whether yours was already repaired is only on NHTSA's site, with the VIN (nhtsa.gov/recalls), which no public interface gives.

How it works​

Each source is read once per interval, one request at a time, a second apart, with a User-Agent naming the integration:

  • CPSC: the recalls of the last 21 days (about 40 a month);
  • openFDA: the enforcement reports of the last 21 days, for each category followed (1,000 at most per request; beyond, the status says some are left out). openFDA answers "not modified" when nothing changed; without a key, its quota is 1,000 requests a day per address, far above what the integration asks;
  • NHTSA: the campaigns of each vehicle.

A recall is new when its number was absent from every answer of its source read before. The first answer of a source fires nothing (what is listed then is not news), nor does a widened selection. A new CPSC or FDA recall whose day is more than 14 days old is remembered without firing; a vehicle campaign fires whatever its day (it is new for your vehicle). A scene event Gladys refuses is sent again at the next reading of its source; at most 20 events leave per check, the rest at the next one, 200 at most waiting per source (beyond, the oldest are dropped and the status says it). An event is sent before /data records it: if the integration is killed in between, it is sent again after the restart.

What was seen, the copy of the recent recalls and the time of the last reading of each source are kept in /data: a restart fires nothing again, keeps the time planned for the next reading, and publishes the copies kept if they are still fresh. A source added by the configuration is read at once; a source taken off and back keeps its time. Configurations saved one after the other are applied in order: the last one wins.

Status and failures​

Each source is independent: one that fails or asks to wait never holds the readings of the others (the counters, though, wait for every source, see below). The status of the integration says:

  • a source cannot be read (network, HTTP error, answer in another format), with its next try: 15 minutes later, then 30, doubled up to the interval; a "429" or "5xx" answer pauses that agency for 1 minute to 6 hours (the server's Retry-After when it gives one), kept across restarts;
  • a VIN cannot be decoded, or is not 17 valid characters (by its position);
  • a vehicle entry is not understood, or there are more than 5 vehicles;
  • a vehicle has no campaign known to NHTSA (check the spelling);
  • openFDA has not loaded new reports for 21 days (compared to the date the server gives): the counters are then not published until it does;
  • nothing is followed;
  • /data cannot be read or written, or does not answer (the readings go on);
  • more than 200 new recalls of a source wait for Gladys (the oldest dropped).

Up to date or not​

The recalls are up to date when every followed source was read successfully less than two intervals and an hour ago, and openFDA is not stale. Otherwise:

  • the counters of the device are not published (they keep their last value): never a count that leaves a source out, never 0 for what is unknown;
  • the scene action fails with the reason ("The recalls are not up to date: CPSC (consumer products) last read on …", "Not read yet: FDA (food).", "Nothing is followed"), so a scene never reads "no recall" from data that is not current;
  • the configuration button gives that reason instead of the recalls;
  • the widget titles "Recalls not up to date" (or "Waiting for the sources", "Nothing followed") and lists the recalls of the sources that are.

When the last reading of a source failed but its recalls are still up to date, the scene action, the button and the widget give them with a warning first ("Warning: the last reading failed for CPSC (consumer products) (…; recalls of …).").

Limits​

  • A complement, not an official alert system: always check the recall sheet. Not affiliated with CPSC, the FDA, NHTSA nor any US agency.
  • openFDA: "Do not rely on openFDA to make decisions regarding medical care"; its reports come once a week, a few days late, and are not every recall of the week (some appear later). FDA reports have no link of their own: the link goes to the FDA recalls page.
  • The vehicle campaigns are those of a make, model and year, not of your vehicle.

Data and licence​

CPSC recalls (saferproducts.gov), openFDA (api.fda.gov) and NHTSA (api.nhtsa.gov, vpic.nhtsa.dot.gov): public data of the US government, read without an account nor a key. See open.fda.gov/license.

Parámetros de configuración​

Estos son los parámetros que Recalls US te pide en su pantalla de configuración en Gladys.

ParámetroTipoObligatorioDescripción
Your selectionsectionNoThree US agencies publish their recalls as open data: CPSC (consumer products), the FDA (food, drugs, medical devices) and NHTSA (vehicles). Choose the categories to follow, brands or words if you like, and your vehicles. Save, then create the device in the Discover tab.
Sources and limitssectionNoData read without an account nor a key: saferproducts.gov (CPSC), openFDA enforcement reports (weekly) and NHTSA. The recalls of a vehicle are those of its make, model and year: NHTSA's site, with the VIN, says whether yours was repaired. A complement, not an official alert system: always check the recall sheet. Not affiliated with any US agency; openFDA data is not for medical decisions.
Categoriesmulti_selectNoRecalls of these categories are followed. About 40 consumer products, 45 food and 50 drug recalls a month (autumn 2026); medical devices, about 250 a month, mostly hospital equipment, are not followed by default.
Brands or words (optional)stringNoOnly the CPSC and FDA recalls naming one of them (title, product or firm), separated by commas. Whole words; accents and case do not matter. Empty: every recall of the categories. Vehicles are not filtered.
Vehicles (optional)stringNoMake, model and model year of each vehicle, separated by semicolons, as NHTSA spells them. Five vehicles at most, VINs included.
VINs (optional)secretNoUp to 3 VINs (17 characters), separated by commas, instead of typing the vehicles. Kept by Gladys in its database, never shown again, sent only to NHTSA (vPIC) to learn the make, model and year; never written in the logs, the status or the memory of the integration.
Check intervalselectNoEach source is read once per interval, one request at a time. The FDA publishes once a week, CPSC a few times a week.
Language of the textsselectNoThe names of the features (at their creation) and the texts sent to the scenes. The recalls themselves are published in English.

Cómo instalar Recalls US en Gladys​

  1. En Gladys, abre Integraciones: Recalls US aparece en el catálogo junto a las integraciones nativas, con una insignia de comunidad.
  2. Haz clic en Instalar. Gladys descarga la imagen Docker (ghcr.io/lm1lc3n7/gladys-recalls-us:0.1.1), la ejecuta en un entorno aislado del núcleo y genera la interfaz de la integración (dispositivos, descubrimiento y configuración).
  3. Abre la pantalla de Configuración de la integración, rellena los parámetros y guarda.
  4. También puedes instalarla directamente desde la URL de su repositorio: https://github.com/LM1LC3N7/gladys-recalls-us.

Recalls US requiere Gladys >=5.1.0. El catálogo de Gladys se actualiza cada hora, así que una nueva versión está disponible como máximo una hora después de publicarse.

¿Todavía no usas Gladys? Es gratuito y de código abierto: sigue la guía de instalación para empezar.

Sobre las integraciones externas​

Recalls US es una integración externa: una integración comunitaria empaquetada como contenedor Docker y publicada en GitHub. Gladys la instala con un clic y la ejecuta en un entorno aislado del núcleo. La publica y mantiene LM1LC3N7, no el equipo principal de Gladys.

Suscríbete a la newsletter de Gladys Assistant