This integration connects your homee box (Z-Wave, Zigbee, EnOcean, depending on its cubes) to Gladys Assistant, locally: the devices paired with the box become Gladys devices, their states follow the box live and Gladys controls them through it.
Unofficial integration, not affiliated with homee GmbH. It has never been tested with a real homee: it was written from the pyHomee library and the homee integration of Home Assistant, and tested against a simulated box. Your feedback is welcome.
What is supported
- Lights: on/off, brightness, colour temperature.
- Plain wall switches (the "on/off switch" profiles, double, with input, Wi-Fi): on/off, dimmer.
- Plugs, metering relays and any other device: state, power, energy (cumulative index), and "Turn on" / "Turn off" buttons behind an option (see below).
- Roller shutters: open, close, stop, position.
- Thermostats and radiator heads: temperature, setpoint, valve opening, battery, heating mode (read).
- Hot water: temperature, setpoint (capped).
- Sensors: opening, window, motion, presence, leak and flood, smoke, carbon monoxide, tamper, low battery, temperature, humidity, illuminance, CO2, UV, wind, rain, current, voltage.
- Locks, garage doors, gates, impulse relays, water valves, sirens, the homee mode: read-only state, and buttons (or a list for the mode) that work only when you allow them. In v1, the Open / Close / Stop buttons exist for motorised garage doors and entrance gates only; other doors and window motors show their state, their impulse buttons stay.
- Remotes and wall buttons (presses), homeegrams and the INOVA alarm (always read-only) are not handled yet.
Configuration
- In the homee app, preferably create a user of its own for Gladys.
- Note the local IP address of the box (Settings → homee, or your router). Give it a fixed address.
- In Gladys, Integrations → homee: type the IP address, the user name and the password, then Test the connection.
- In the Discovery tab, add the devices you want.
The password is a secret field: it is kept by Gladys in its database, never shown again, and sent only to your homee (as its SHA-512 fingerprint, like the homee apps do). The integration only uses the local connection of the box (port 7681), never my.hom.ee.
Safety: what stays read-only
A "turn everything off" (Google Home, Alexa, HomeKit, MCP, a scene) must never reach a valve, a lock, a siren, a heating or an unknown load. Only lights and plain wall switches therefore get a switch in Gladys; every other device has a read-only state and buttons, refused while the matching option is off (all are off by default):
| Option | What it allows |
|---|---|
| Allow plug control | Turn on / Turn off buttons of plugs, metering relays and other devices |
| Allow heating control | Thermostat and hot water setpoints, on/off of electric heaters |
| Allow lock control | Lock, Unlock, Unlatch |
| Allow door and gate control | Open, Close, Stop (garage doors, entrance gates), impulses |
| Allow valve control | Open / Close water valves |
| Allow siren control | Sound / Stop the siren |
| Allow changing the homee mode | Home, Sleeping, Away, Vacation (a list) |
For each of these commands, the integration reads the state of the device just before, refuses when that state is unknown or moving (a door whose target differs from its position is moving), checks the option one last time just before sending, and waits for the box to confirm. Without a confirmation in time, Gladys shows "Command sent, without confirmation from the homee": check the device.
The protective commands — lock, close the valve, stop a door, turn off, stop the siren — are never refused because of the state of the device and are always sent (a leak while a valve opens must be able to close it). No command waits behind the confirmation of another. A lock, a door or a valve that does not report the state asked for in time (30 s, 90 s, 60 s) shows "State not confirmed" on its badge, until it reports a state. Two presses of an impulse button less than 2 s apart count as one. A door whose direction (reversed or not in homee) is unknown or changed since it was added refuses Open / Close. A command that cannot leave within 3.5 s is refused, never sent late.
The hot water setpoint is capped at 55 °C by default (scalding risk), adjustable up to 60 °C at most, the setpoint of a warm water circuit included. Any setpoint outside the range shown in Gladys is refused. The valves of radiator heads are never controlled directly: they follow their setpoint. On an on/off water valve, the meaning of "on" (open or closed) is still to be checked on a real box: the buttons are therefore named "Turn on" / "Turn off".
Energy
The cumulative energy of a plug or a meter is an index Gladys bills: every rise is counted in full. The integration guards it like the P1 Monitor integration does:
- never 0; a drop or an implausible jump (more than 25 kW on average since
the last reading) is held: the last accepted value is sent again, the
badge of the device shows the kWh waiting, and the log says so; the hold is
kept in
/data, even across a restart; - it is never confirmed by repetition nor by time: only the "Accept the held index" action of the configuration takes it, in two clicks. The first click takes nothing: it lists every index held on the device chosen (feature, drop or jump, from → to, kWh). A second click within 60 s takes exactly that list — each value shown, plus what the device may draw until its next reading — and answers with the kWh counted; if the list changed meanwhile, it is listed again. The badge of the device sums up all its holds (how many, the kWh at stake). Saving the configuration or a reconnection never accepts anything;
- a device added again starts from a fresh guard;
- the total of an energy meter (which may also count the plugs of the box) is a plain value, never an index: the energy of the plugs is not counted twice.
Connection and errors
- A token is asked from the box when connecting and kept in memory only; it is renewed before its end, never in a loop. When the box refuses the live connection while its port answers, a new token is asked at the next try; a network failure keeps the token.
- A lost live connection is opened again after 5 s, then 10 s, 20 s… up to 5 minutes between two tries. The whole box is read again every 10 minutes; without an answer within 30 s, the connection is opened again.
- Refused credentials: the integration stops and notes it in
/data(without the user name or the password, only a salted fingerprint). Next automatic try after 1 h, then 2 h, 4 h… up to 24 h; "Test the connection" or saving the configuration tries at once (the same credentials refused again wait longer). - If the box asks to slow down (HTTP 429), the integration pauses (1 minute to 6 hours), kept even across a restart.
- "Test the connection" reuses the connection in use when there is one.
Known limits
- Never tested with a real homee (see above): the profiles and the meaning of some values come from pyHomee and Home Assistant.
- Feature names are set when the device is added.
- Remote presses, homeegrams, groups and the INOVA alarm are not handled yet.
Credits
- pyHomee (MIT), the library of the homee integration of Home Assistant, whose protocol is ported.
- The homee integration of Home Assistant (Apache-2.0), for the meaning of the profiles and values.
- The energy index guard comes from the Gladys P1 Monitor integration (LM1LC3N7/gladys-p1-monitor).
Parámetros de configuración
Estos son los parámetros que homee te pide en su pantalla de configuración en Gladys.
| Parámetro | Tipo | Obligatorio | Descripción |
|---|---|---|---|
| Your homee devices in Gladys | section | No | The devices paired with your homee box (Z-Wave, Zigbee, EnOcean) are offered in the Discovery tab: lights, switches, plugs, shutters, thermostats, contact, motion, leak, smoke sensors, temperature, humidity, consumption. The states follow the box live, through its local connection only. Plugs, heating, locks, doors and gates, valves, sirens and the homee mode stay read-only until you allow them below, and they are never switches. Never tested with a real box yet. Unofficial, not affiliated with homee. |
| Address of the homee | string | Sí | The local IP address of your homee box, like 192.168.1.60 (shown in the homee app, Settings → homee). Local only: not my.hom.ee. |
| homee user name | string | Sí | A user of the homee box, the one you log in with in the homee app. A user of its own for Gladys is best. |
| Password | secret | Sí | The password of this homee user. Kept by Gladys in its database, never shown again, and sent only to your homee. |
| Language of the feature names | select | No | Used for the names of the features of the devices added from now on. |
| Minimum interval between two readings of a sensor (s) | number | No | Some devices report every second (power meters): Gladys keeps the last reading at this pace. Switches, lights, contact and motion sensors are never delayed. |
| Allow plug control from Gladys | boolean | No | Off by default: the load behind a plug, a metering relay or any device that is not a light nor a plain wall switch is unknown (a heater, a freezer…), so it is never a switch: its state is read-only and it has "Turn on" and "Turn off" buttons, which work only when this option is on. |
| Allow heating control from Gladys | boolean | No | Off by default: setpoints of thermostats and hot water, and the on/off buttons of electric heaters, are read-only. On, Gladys can change them, from the dashboard and scenes. |
| Highest hot water setpoint (°C) | number | No | A hot water setpoint above it is refused (scalding risk): 55 °C by default, 60 °C at most. |
| Allow lock control from Gladys | boolean | No | Off by default: locks are read-only. On, their "Lock", "Unlock" and "Unlatch" buttons work, from the dashboard and scenes. |
| Allow door and gate control from Gladys | boolean | No | Off by default: garage doors, gates, doors, window motors and impulse relays are read-only. On, their "Open", "Close", "Stop" and impulse buttons work. |
| Allow valve control from Gladys | boolean | No | Off by default: water valves are read-only. On, their open and close buttons work. Radiator valves always follow their thermostat. |
| Allow siren control from Gladys | boolean | No | Off by default: sirens are read-only. On, their "Sound the siren" and "Stop the siren" buttons work. |
| Allow changing the homee mode from Gladys | boolean | No | Off by default: the mode of the box (home, sleeping, away, vacation), which your homeegrams may use to arm an alarm, is read-only. On, it can be chosen from a list. The INOVA alarm is always read-only. |
Cómo instalar homee en Gladys
- En Gladys, abre Integraciones: homee aparece en el catálogo junto a las integraciones nativas, con una insignia de comunidad.
- Haz clic en Instalar. Gladys descarga la imagen Docker (
ghcr.io/lm1lc3n7/gladys-homee:0.1.1), la ejecuta en un entorno aislado del núcleo y genera la interfaz de la integración (dispositivos, descubrimiento y configuración). - Abre la pantalla de Configuración de la integración, rellena los parámetros y guarda.
- También puedes instalarla directamente desde la URL de su repositorio: https://github.com/LM1LC3N7/gladys-homee.
homee requiere Gladys >=5.1.0. El catálogo de Gladys se actualiza cada hora, así que una nueva versión está disponible como máximo una hora después de publicarse.
¿Todavía no usas Gladys? Es gratuito y de código abierto: sigue la guía de instalación para empezar.
Sobre las integraciones externas
homee es una integración externa: una integración comunitaria empaquetada como contenedor Docker y publicada en GitHub. Gladys la instala con un clic y la ejecuta en un entorno aislado del núcleo. La publica y mantiene LM1LC3N7, no el equipo principal de Gladys.
- Explorar todas las integraciones, nativas y de la comunidad
- Crear y publicar tu propia integración externa
- Código fuente en GitHub — fuente de esta documentación