Vogel's MotionMount smart home integration, free and open source

Vogel's MotionMount integration for Gladys Assistant

Vogel's MotionMount motorized TV mounts over their local network. Unofficial.

This integration connects Gladys to your Vogel's MotionMount motorized TV mount (Signature, TVM 7675 Pro) over its local protocol (TCP, port 23, on the Ethernet cable of the mount). The MotionMount becomes a device in the Discovery tab of Gladys: position, motion, errors, a list to go to a preset and a Stop button. Everything stays on your local network. Unofficial, not affiliated with Vogel's.

Development version (0.1). Written from the python-MotionMount library published by Vogel's, and tested against a simulated MotionMount only: it has never been tested with a real MotionMount yet. Feedback is welcome on the GitHub repository.

Safety first​

A motorized mount can pinch a hand between the TV and the wall, or hit a person, a piece of furniture or an object. That is why:

  • moves are off by default: tick "Allow moves" first;
  • a move goes through a list ("Go to a preset"), never a switch: a "turn everything off" scene or voice assistant does not trigger it;
  • a preset beyond the bounds you choose (extension, turn) is refused;
  • a move is refused while the mount reports an obstruction, a motor error, an internal error or a TV width error;
  • the Stop button does not depend on the moves option.

The protections of the mount itself (obstruction detection) come first: only automate a move when nobody can stand in its way.

What you get​

FeatureIn Gladys
Extension (%)0 = against the wall, 100 = arm fully out (read only)
Turn (%)-100 to 100 (read only)
Movingthe motors run (read only)
Status"OK" or the errors the mount reports (read only)
Go to a presetthe wall, or a preset 1 to 7 set on the mount; off by default
Stopstops the mount where it is

Positions are those of the mount (percent of its travel), not centimetres nor degrees. Presets are set in the Vogel's app; the list follows their names at each read.

Requirements​

  • A MotionMount Signature (TVM 7675 Pro) wired with an Ethernet cable to the network of Gladys (the RS-232 link is not supported).
  • Its IP address, preferably fixed (reserved in your router). Names in .local do not resolve in the integration container.
  • If a PIN of the User level is set on the mount: that PIN.
  • A firmware that gives the MAC address of the mount (mac): it is the identity of the device in Gladys. An older mount without it is not added (the status says so).

Setup​

  1. In Gladys, open the Vogel's MotionMount integration, Configuration tab.
  2. Type the address of the MotionMount, like 192.168.1.50 (or 192.168.1.50:2323 for another port).
  3. Only when the mount has a PIN: type it in PIN. It is kept by Gladys in its database, never shown again; it is sent only to the MotionMount, and only when the mount asks for it, once per connection.
  4. Save, then click Test the connection: the state of the mount shows.
  5. Open the Discovery tab and add the MotionMount.
  6. To control the moves, tick Allow moves and set the bounds.

Options​

  • Allow moves (off by default): "Go to a preset" moves the TV.
  • Maximum extension (100 % by default) and Maximum turn (100 % by default, each side): a preset beyond them is refused. The wall (extension 0, turn 0) is always within them.
  • Read interval (60 s by default, 30 to 600 s): how often the state is read again. The mount also tells its changes on the connection, which stays open. After a command, the state is read at 2, 8, 20 and 45 s.
  • Language of the feature names.

How the commands are handled​

Go to a preset: right before acting, the integration reads the errors of the mount and the preset asked (set? within the bounds?), then sends the command. One move at a time: the next one waits until the previous one is sent. The command is refused, nothing sent, when:

  • the value is not a preset from 0 to 7, or no address is configured;
  • the moves option is off (checked on arrival, after the reads and right before sending);
  • the mount is not connected (or its first read is not finished), or its identity (MAC address) is not the one of the device;
  • the mount asks for a PIN that is missing, refused, or asks to wait after failed attempts, or the connection was cut twice in a row right after the PIN was sent;
  • the previous move left without confirmation less than 30 s ago and the mount has not reached it yet;
  • the mount could not be read before acting (no answer, connection lost, value not readable);
  • the preset is not set, or is beyond the bounds;
  • the mount reports an error (obstruction, motor, internal, width);
  • a stop arrived meanwhile, or the configuration changed meanwhile;
  • the connection was lost before sending, or the command could not leave within 3.5 s.

Once the command is written:

  • the mount may refuse it itself (#4xx): nothing is done, the refusal is reported;
  • without an answer of the mount, it is reported "sent, without confirmation", and never sent again by itself.

Stop: the MotionMount protocol has no stop command. The integration reads the current position and sends it back as the new target: the motors stop where they are. A position read up to 5 points outside the travel (mechanical play) is brought back to the bound; further, nothing is written.

  • The stop does not depend on the moves option and cancels the moves not sent yet.
  • It goes before the other requests not sent yet, and waits 1 s at most for the request on the wire, a previous stop included (then the connection is cut and opened again).
  • Each read of the stop waits 1.5 s at most; when a read fails before sending (a stale or cut connection), a new connection is opened and the stop tried once more, within the deadline.
  • When the mount is not connected, the stop opens a connection at once, even during the wait after a failure.
  • Several presses while a stop is not sent yet share that stop.
  • While the container starts, the stop waits for the configuration (2 s at most).
  • When a PIN is typed and the mount asks for it, the stop sends it; a PIN the mount refused is not sent again, but one held because of two cuts is (once per press).

1.5 s after a stop (answered, or sent without an answer), the integration reads the motion of the mount (opening a connection when needed). When it still moves, or cannot tell, the stop is sent again, and so on, 3 times at most; a re-send that fails does not end these rounds. They end when a move was sent after the stop, or when the configuration changes. They are not kept in /data: a restart of the container in the seconds after the stop loses them.

The cases where the stop fails:

  • no address is configured (after the wait of the start);
  • the mount does not answer: no connection, or reads without an answer on the first connection and then on the new one;
  • the current position cannot be read, or is not understood (too far outside the travel): nothing is written;
  • the mount refuses the stop or a read (#401: PIN missing, refused or a wait imposed; #400, #403, #405...);
  • the stop could not leave within 3.5 s;
  • it is written without an answer: "sent, without confirmation" (then checked as above);
  • it went to another MotionMount than the one of the device (another MAC address answers at the address): sent, but reported, since the mount of the device may not be stopped.

Privacy and security​

  • The PIN is written neither to the logs, nor to the connection status, nor to /data. An address the integration does not understand is not shown back either (only its length): a PIN pasted in the wrong field does not show.
  • When the mount refuses the PIN (or the connection is cut twice in a row right after it), only an 8-bit mark (a truncated salted hash, shared by about 39 PINs out of 9999) is kept in /data, to see that the PIN typed changed. The PIN is not sent again by itself until another PIN or a click on Test the connection (one try); only the stop still sends it, once per press, when the hold comes from cuts.
  • The MotionMount protocol travels in clear on your local network.
  • No cloud, no account, no Bluetooth.

Troubleshooting​

  • Unreachable: check the IP address and the Ethernet cable; the mount answers on port 23. After a failure, the integration tries again after 30 s, 1, 2 then 5 min, and at least the interval (the Test the connection button too, restarts included: the time of the last attempt is kept in /data). Exceptions: a stop and its checks, and the reads that follow a command, may open a connection sooner.
  • Identity cannot be read: firmware too old (no MAC address); update the mount with the Vogel's app.
  • Preset not reached (orange dot): an obstruction, a hand on the TV or a stop interrupted the travel.

Configuration settings​

These are the settings Vogel's MotionMount asks for in its configuration screen in Gladys.

SettingTypeRequiredDescription
Your MotionMount in GladyssectionNoThe MotionMount (Signature, TVM 7675 Pro) becomes a device in the Discovery tab: extension, turn, motion, errors, a list to go to a preset and a Stop button. Everything stays on your local network (TCP port 23, Ethernet). Moves are off by default: a motorized mount can pinch or hit. Never tested with a real MotionMount yet. Unofficial, not affiliated with Vogel's.
Address of the MotionMountstringYesIts local IP address (port 23 by default, or address:port). Give it a fixed address in your router (DHCP reservation). One MotionMount per integration.
PIN (optional)secretNoOnly if a PIN of the User level is set on the mount (a number from 1 to 9999). Kept by Gladys in its database, never shown again; sent only to the MotionMount, and only when it asks for it.
Allow movesbooleanNoOff by default. On, "Go to a preset" moves the TV (the wall or a preset set on the mount), from Gladys, scenes or voice assistants. Make sure nobody and nothing stands in its way. Stop does not depend on this option.
Maximum extension (%)numberNoA preset whose extension goes beyond it is refused (0 to 100 %, 100 = the full arm).
Maximum turn (%)numberNoA preset turned further, on either side, is refused (0 to 100 %).
Read interval (s)numberNoHow often the state is read again (30 to 600 s); the mount also tells its changes as they come. After a failure, the next connection waits at least this long.
Language of the feature namesselectNoUsed for the names of the features and presets of the mount added from now on.

How to install Vogel's MotionMount in Gladys​

  1. In Gladys, open Integrations: Vogel's MotionMount appears in the catalog, next to the native integrations, with a community badge.
  2. Click Install. Gladys pulls the Docker image (ghcr.io/lm1lc3n7/gladys-motionmount:0.1.1), starts it in a sandbox isolated from the core, and generates the integration's interface (devices, discovery and configuration).
  3. Open the Configuration screen of the integration, fill in the settings, and save.
  4. You can also install it directly from its repository URL: https://github.com/LM1LC3N7/gladys-motionmount.

Vogel's MotionMount requires Gladys >=5.1.0. The catalog inside Gladys refreshes every hour, so a new version becomes available at most one hour after its release.

Not running Gladys yet? It is free and open source: follow the installation guide to get started.

About external integrations​

Vogel's MotionMount is an external integration: a community integration packaged as a Docker container and published on GitHub, that Gladys installs in one click and runs in a sandbox isolated from its core. It is published and maintained by LM1LC3N7, not by the Gladys core team.

Subscribe to the Gladys Assistant newsletter

A few emails per month about new releases and project news. Sent by Pierre-Gilles Leymarie, founder of the project. Unsubscribe anytime 🙂