Vallox smart home integration, free and open source

Vallox integration for Gladys Assistant

Control your Vallox heat recovery ventilation unit locally: profiles, fans, temperatures.

Control your Vallox heat recovery ventilation unit (MVHR) from Gladys Assistant: profiles (home, away, boost, fireplace), fan speeds, supply air temperatures, and every sensor of the unit (temperatures, humidity, CO2, filter). Scene triggers, scene actions and a dashboard widget come with it.

Everything stays on your local network: the integration talks to the unit the way its own web interface does. No cloud account, no internet access needed.

Supported units​

Vallox units with the MV controller and a network port, which have a web interface reachable at http://<unit address>: Vallox 51/90/96/99/101/110/125/139/145/245 MV, ValloPlus 180/240/270/350/ 370/510/850 MV, ValloMulti 200/300 MV, TSK Multi MV, and the Helios KWL units built on the same controller.

Older units without a network port (Digit SE, Digit 2…) are not supported.

Before you start​

  1. Connect the unit to your network (cable on the unit's Ethernet port).
  2. Give it a fixed IP address in your router (DHCP reservation): the integration finds the unit by its address.
  3. Check that http://<that address> opens the Vallox web interface in a browser, from a computer on the same network as Gladys.

Installation​

In Gladys, go to Integrations, search for Vallox and install it.

Configuration​

FieldWhat to put
IP address of the unitThe address of the unit, e.g. 192.168.1.50. Several units: separate with commas.
Refresh interval (s)How often the unit is read. 60 s by default, 15 s minimum.
Filter warning (days)The "Filter change due" trigger fires when the filter life left reaches this value.

Save, then click Test the connection: the answer gives the model, the firmware, the profile and the temperatures of each unit, or the reason why it did not answer.

Then go to Discover in the integration and create the device.

The device​

The unit becomes one Gladys device, named after its model. It is identified by the unique id the unit carries: changing its IP address later does not create a new device.

FeatureTypeWhat it does
Ventilation on/offswitchStops or starts the unit
Away modeswitchAway profile on / back to home
BoostswitchBoost for the duration set on the unit / stop the boost
Fireplace modeswitchFireplace mode for the duration set on the unit / stop
Fan speedsensor (%)Current fan speed
Indoor air (extract)temperatureAir extracted from the rooms
Outdoor airtemperatureFresh air coming in
Supply airtemperatureAir blown into the rooms
Exhaust airtemperatureAir leaving the house
Humidityhumidity (%)If the unit has the sensor
CO2CO2 (ppm)If the unit has the sensor
Fan speed (home/away/boost)setting (%)Fan speed of each profile
Supply air target (home/away/boost)setpoint (°C)Supply air temperature of each profile (5 to 25 °C)
Boost / fireplace time leftduration (min)Time left of the running boost or fireplace mode
Filter change induration (days)Days left before the next filter change

The device card shows a local badge while the unit answers, unreachable when it does not.

Scenes​

Triggers​

TriggerWhenVariables
Ventilation profile changedThe profile changed from the unit's panel, its app or a timerunit name, new profile, previous profile
Ventilation alarmA new alarm is active (fan fault, frozen cell, dirty filters…)unit name, severity, alarm, code, message
Filter change dueThe filter life left reached the number of days set in the configurationunit name, days left, change date
Ventilation unit unreachableThe unit stopped answering (two reads in a row failed)unit name, address

Each trigger can be limited to one unit, and "profile changed" to some profiles, "alarm" to a severity.

Orders given by Gladys (dashboard, scenes, widget) never fire "profile changed": a scene that reacts to a profile change and changes it again cannot loop.

Profile values in the variables: home, away, boost, fireplace, extra.

Actions​

ActionWhat it doesResult for the next actions
Set the ventilation profileHome, away, boost or fireplace; optional duration in minutesprofile
Set the fan speed of a profileFan speed (%) of the home, away or boost profilefan speed
Record a filter changeThe filters were changed today: the unit restarts its remindernext change date
Read the ventilation valuesReads the unit nowprofile, temperatures, humidity, CO2, fan speed, filter days left

Example: when the bathroom humidity goes above 75 %, set the profile to boost for 30 minutes.

Dashboard widget​

Add the Vallox ventilation widget to a dashboard. It shows:

  • live tiles: indoor and outdoor temperature, fan speed, and CO2 (or humidity, or supply air);
  • a status list: profile and time left, heat exchanger state (heat recovery, bypass, defrost), filter change, alarms, connection;
  • three buttons: Home, Away, Boost.

With several units, pick the unit in the widget settings.

Configuration screen buttons​

  • Test the connection: reads each unit now and tells what it found.
  • Filters changed today: after changing the filters, choose the unit; its reminder restarts from today.

Troubleshooting​

ProblemWhat to check
"No answer from 192.168.1.50"The address, the cable, and that http://<address> opens in a browser on Gladys' network.
The device is not in DiscoverThe unit must have answered once: click Test the connection, then Discover again.
Humidity or CO2 stays emptyThe unit has no such sensor: the value is not published.
The values arrive lateLower the refresh interval (15 s minimum).
The Vallox app stops workingThe unit accepts few connections at a time: avoid a refresh interval below 30 s.

The integration logs (Integrations → Vallox → Logs) say which unit failed and why.

Privacy​

The integration only talks to the address you typed, on your local network (port 80). Nothing is sent to Vallox or to any other service. The only file it writes is /data/units.json, which keeps the id, model and firmware of the units already met.

Configuration settings​

These are the settings Vallox asks for in its configuration screen in Gladys.

SettingTypeRequiredDescription
Getting startedsectionNoThe integration talks to the unit directly on your local network, like the Vallox web interface does: no cloud account. Give the unit a fixed IP address in your router, check that you can open http://<that address> in a browser, then type the address below.
IP address of the unitstringYesSeveral units: separate their addresses with commas.
Refresh interval (s)numberNoHow often the unit is read, in seconds (15 to 3600).
Filter warning (days)numberNoThe "Filter change due" scene trigger fires when the filter life left reaches this number of days.

How to install Vallox in Gladys​

  1. In Gladys, open Integrations: Vallox appears in the catalog, next to the native integrations, with a community badge.
  2. Click Install. Gladys pulls the Docker image (ghcr.io/prohand/gladys-vallox:1.0.1), starts it in a sandbox isolated from the core, and generates the integration's interface (devices, discovery and configuration).
  3. Open the Configuration screen of the integration, fill in the settings, and save.
  4. You can also install it directly from its repository URL: https://github.com/prohand/gladys-vallox.

Vallox requires Gladys >=5.3.0. The catalog inside Gladys refreshes every hour, so a new version becomes available at most one hour after its release.

Not running Gladys yet? It is free and open source: follow the installation guide to get started.

About external integrations​

Vallox is an external integration: a community integration packaged as a Docker container and published on GitHub, that Gladys installs in one click and runs in a sandbox isolated from its core. It is published and maintained by prohand, not by the Gladys core team.

Subscribe to the Gladys Assistant newsletter

A few emails per month about new releases and project news. Sent by Pierre-Gilles Leymarie, founder of the project. Unsubscribe anytime 🙂