V2C Trydan smart home integration, free and open source

V2C Trydan integration for Gladys Assistant

V2C Trydan EV chargers over the local API: state, power, current, solar control; optional commands.

Shows your V2C Trydan charging station in Gladys through its local API: no cloud, no account, straight on your network.

Unofficial API, never tested with a real station. Not affiliated with V2C. It talks to the local API of the station as the pytrydan library (used by Home Assistant) does. V2C may change it without notice.

What you get​

One device per station with:

FeatureContent
StatusNo vehicle, plugged in, charging, paused, station locked, faults
ConnectorAvailable, occupied, faulted or unavailable (Gladys' "charging station" category)
Charging stateCharging, vehicle plugged in, paused (by the station), idle
Vehicle plugged inYes / no
Charging powerIn W
House, solar, battery powerIn W, measured by the clamp or inverter linked to the station (house negative on export)
Installation voltageIn V, when the station gives it
Energy of the sessionIn kWh, a plain sensor
Duration of the sessionIn seconds
Charging, minimum, maximum currentIn A: the current setpoint and the range set on the station
Charge paused, station locked, schedule on, dynamic modulation, modulation paused, readyYes / no, read only
Wiring (phases)Single-phase, three-phase, mixed (read only)
Solar control modeSchedule, no schedule, solar + minimum power, solar only, solar + grid, stop
Meter linkNo error, clamp not connected, Modbus errors…
Pause chargingButton (commands allowed only)
Resume chargingButton (commands allowed only)
Set the charging currentList of 6 to 32 A (commands allowed only)
Set the solar control modeList of the six modes (commands allowed only)

Read every 30 seconds by default (10 s to 10 min, configurable).

Energy: the energy of the session is a plain sensor, never an index: it does not enter Gladys' Energy tab (the station is already counted by your main meter). No daily consumption is published.

Installation​

  1. Give the station a fixed IP address in your router.
  2. Install the integration from the Gladys store.
  3. In its configuration, enter the IP address of the station (or its host name; several stations: separated by commas, four at most). Loopback (127.x), multicast and broadcast (ending in .255) addresses are refused, and a host name is only followed when it points to an IPv4 device address.
  4. Save, then add the station from the Discovery tab.

The device takes the identifier (ID) the station gives, kept for its address (across restarts too): a read that misses it once does not change the device. But a command needs the read just before to really give that identifier: otherwise it is refused unsent ("the station did not give its identifier"), so that another station that took the address is never driven. Some firmware versions never give one: the device then takes the address typed, and changing that address creates a new device.

The same station typed twice (its IP address and its host name, for instance): it gives the same identifier, so a single device; it is read twice per interval, and the commands go through the address that answers (the first one typed when both do). Type it once. Without an identifier, each address gives its own device.

The Test the connection button reads each station once (at most every 10 seconds).

Security: an API without a password​

The local API of the Trydan has no authentication at all: any machine on your network can read the station and drive it (pause, current, mode), Gladys included. This module assumes a trusted network: never make the station reachable from the Internet (no port forwarding), and preferably put it on a separate network for connected devices. This module asks for and keeps no secret.

Commands (off by default)​

"Pause charging", "Resume charging", "Set the charging current" and "Set the solar control mode" refuse every command while the Allow the commands option is off. On:

  • Pause suspends the charge (Paused=1); it is never blocked: not by a command in flight (it leaves at once, without a read, and once more when that command ends), not by a once-a-minute limit. An older command that has not left yet gives way to it. A second pause while the first one is being sent is refused ("a pause is already being sent");
  • Resume restarts the charge (Paused=0); refused when the station reports a fault or an unknown state;
  • Charging current: whole amperes, 6 to 32 A, and always within the range set on the station (minimum and maximum current read just before); refused when the station does not give that range;
  • Solar control: the dynamic power mode of the station (see below). Any mode but "Stop" may take power and so start a charge: like "Resume", it is refused when the station reports a fault or an unknown state.

One change a minute at most per station for the current, the solar control and resume (not meant for fine regulation); never for the pause.

The solar control modes​

What pytrydan says of each value (DynamicPowerMode); the exact effect depends on the station and its installation (not checked):

  • Schedule (app or V2C cloud): the station follows the time profile set in the V2C app; it may charge from the grid;
  • No schedule: the time profile is off; the station charges from the grid at the current setpoint;
  • Solar + minimum power: the solar surplus, plus a minimum power taken from the grid;
  • Solar only: the solar surplus only;
  • Solar + grid: the solar surplus, topped up from the grid;
  • Stop: the "stop" mode of the station, which takes no power; it is not the same as "Pause charging" (Paused): to suspend a charge, use the pause.

The solar modes only act when dynamic modulation is on in the station (in the V2C app): with "Dynamic modulation" at no, a mode change is accepted but has no effect, and the configuration screen says so. With dynamic modulation, the station sets its current itself: the "charging current" sent from Gladys is not a ceiling and may be replaced by the station.

Neither the lock, the wiring (phases), the current range, the schedule nor the contracted power can be changed from Gladys.

They are buttons and lists, never switches: a "turn everything off" (from Gladys, Google Home, Alexa or HomeKit) does not touch them. A scene can trigger them, but only through an explicit action, and only when the commands are allowed. Beware: Gladys' AI chat (MCP) can create and run such a scene: while the commands are allowed, it can resume the charge or change the current.

Before each command, the integration reads the station again and decides on that read only; the option is checked again right before sending. A useless command (already so) is not sent. A command that cannot leave within 3.5 seconds is refused unsent. When the station does not confirm (silence, a 5xx error, an answer other than "OK"), Gladys shows "Command sent, without confirmation": check the state, read again 5 then 20 seconds later. The station answers "OK" when it accepts a setting; when the read after shows it did not apply it (solar control, schedule…), the configuration screen says so. One command at a time per station, the pause aside.

Errors and limits​

  • Station unreachable: only the connector ("unavailable") and the status ("Station unreachable") change; the other values keep their last value. A station removed from the configuration, or that never answered since the start, shows the same, and the configuration screen names it. New tries after 30 s, 1, 2 then 5 minutes, never faster than the interval.
  • 429 (too many requests), unlikely from a local station: a pause of 1 minute to 6 hours for everything (reads, button, commands), never shorter than the refresh interval, kept in /data across a restart.
  • The wiring (ChargeMode) is missing from the main read of some firmware versions: it is then read alone, at most once an hour.
  • The station gives no measured current: "Charging current" is the setpoint.
  • The logs never contain the text of the answers of the station.

Credits​

Ported from pytrydan (Diogo Gomes, MIT, version 1.0.6). Apache-2.0 license.

Configuration settings​

These are the settings V2C Trydan asks for in its configuration screen in Gladys.

SettingTypeRequiredDescription
Your V2C TrydansectionNoShows your V2C Trydan charging station in Gladys through its local API, without any cloud: state, charging power, house, solar and battery power, charging current and its range, energy and duration of the session, pause, lock, schedule, solar control mode. Enter the IP address of the station (give it a fixed address in your router), save, then add it from the Discovery tab. The local API has no password: anyone on your network can read and drive the station. Pausing, resuming, the current and the solar mode can be changed from Gladys only if you allow the commands below. Unofficial API, never tested with a real station. Not affiliated with V2C.
IP address of the stationstringYesAn IPv4 address or a host name of your network (loopback, multicast and broadcast addresses are refused). Several stations: separate them with commas, four at most.
Allow the commandsbooleanNoOff by default. On: Gladys may pause and resume the charge, set the charging current (within the minimum and maximum of the station) and the solar control mode. Off: these four features refuse every command.
Refresh interval (s)numberNoHow often each station is read, in seconds.
Language of the feature namesselectNoUsed for the feature names of the devices added from now on, for the status texts and for the command errors.

How to install V2C Trydan in Gladys​

  1. In Gladys, open Integrations: V2C Trydan appears in the catalog, next to the native integrations, with a community badge.
  2. Click Install. Gladys pulls the Docker image (ghcr.io/lm1lc3n7/gladys-v2c-trydan:0.1.1), starts it in a sandbox isolated from the core, and generates the integration's interface (devices, discovery and configuration).
  3. Open the Configuration screen of the integration, fill in the settings, and save.
  4. You can also install it directly from its repository URL: https://github.com/LM1LC3N7/gladys-v2c-trydan.

V2C Trydan requires Gladys >=5.1.0. The catalog inside Gladys refreshes every hour, so a new version becomes available at most one hour after its release.

Not running Gladys yet? It is free and open source: follow the installation guide to get started.