Solar-Log smart home integration, free and open source

Follow the production, consumption and surplus of your solar plant with a Solar-Log.
Follow your solar plant in Gladys with a Solar-Log data logger (Solar-Log 200, 250, 300, 500, 1000, 1200, 1900, 2000, Solar-Log Base…): production, consumption, surplus, yields, inverters and battery. The integration reads the Solar-Log on your local network through its open JSON interface: no cloud account, no data leaves your home.
What you get
- A Solar-Log device: production power, DC power, AC and DC voltages, total yield (kWh meter), and — when a consumption meter is wired to the Solar-Log — consumption power, total consumption, surplus (production minus consumption) and self-consumption rate.
- One device per inverter with its live power (optional).
- A battery device (level, charge and discharge power) when the Solar-Log manages one.
- Scene triggers: production started / stopped, solar surplus available / ended, Solar-Log unreachable / reachable again.
- Scene actions: read the solar values, check the solar surplus, get the yield of a period.
- Two dashboard widgets: "Solar production" and "Solar yields".
The total yield is published as a meter index: Gladys energy monitoring computes the production of any day, month or year from it.
Before you start
- Give the Solar-Log a fixed IP address in your router (DHCP reservation).
- Open the Solar-Log web page in a browser (its IP address).
- Go to Configuration > System > Access control and turn on Open JSON interface. Save. Without it, the Solar-Log answers nothing to the integration.
- Optional: if the "user" access level is protected by a password, note it. It is needed only for the per-inverter and battery data.
Configuration
In Gladys, open Integrations > Solar-Log > Configuration:
| Field | What to enter |
|---|---|
| Solar-Log address | IP address or host name, e.g. 192.168.1.20 (http:// is added for you). |
| User password | Only if the "user" access level has a password. Stored as a secret. |
| Refresh interval (s) | How often the Solar-Log is read. 60 s by default, 30 s minimum. |
| Production threshold | Production (W) that fires "Solar production started". 50 W by default. |
| Surplus threshold | Surplus (W) that fires "Solar surplus available". 1000 W by default. |
| Surplus margin | "Surplus ended" fires at threshold minus this margin. 200 W by default. |
| One device per inverter | Also create one device per inverter. On by default. |
Then click Test the connection: the answer shows the production right now and the yield of the day. Open the Discovery tab and add the devices you want. Search for inverters again re-reads the inverters and the battery after a change on the Solar-Log.
Scene triggers
| Trigger | When | Variables |
|---|---|---|
| Solar production started | Production goes above the production threshold (morning). | production_w |
| Solar production stopped | Production falls below half of the threshold (evening). | yield_today_kwh |
| Solar surplus available | Production minus consumption reaches the surplus threshold. | surplus_w, production_w, consumption_w |
| Solar surplus ended | The surplus falls below the threshold minus the margin. | surplus_w, production_w, consumption_w |
| Solar-Log unreachable | Three reads in a row failed. Filter on the reason if needed. | reason |
| Solar-Log reachable again | The Solar-Log answers again. |
Each trigger fires once per change, never at every read, and not when the integration restarts. The surplus triggers need a consumption meter on the Solar-Log.
Scene actions
- Read the solar values: reads the Solar-Log now. Outputs:
reachable,production_w,consumption_w,surplus_w,yield_today_kwh,self_consumption_percent. - Check the solar surplus: is the surplus at least the minimum you set? Outputs:
available(never true when the Solar-Log does not answer),surplus_w. - Get the solar yield: production and consumption in kWh for today, yesterday, this month, this year or since installation.
Example: "When the solar surplus is available, between 10:00 and 16:00, turn on the water heater plug; when the surplus ends, turn it off."
Dashboard widgets
- Solar production: live production, consumption and surplus, the share of the peak power, a 24-hour chart, the yield of the day, the link state and a Refresh button.
- Solar yields: production and consumption today, yesterday, this month, this year and in total, plus the current self-consumption.
Troubleshooting
- "The open JSON interface is disabled": turn it on (see "Before you start").
- "The Solar-Log does not answer": check the address, that Gladys and the Solar-Log are on the same network, and that no firewall blocks port 80.
- "The Solar-Log refused the password": check the password of the "user" access level. The plant summary still works without it; only the inverters and the battery need it.
- Values at 0 right after a Solar-Log restart: the integration ignores them on purpose until the Solar-Log has finished starting.
- No inverter device: the per-inverter data may require the password; click Search for inverters again after entering it.
Privacy
Everything stays on your network: the integration only talks to your Solar-Log. The password is stored as a Gladys secret and never written in the logs.
Configuration settings
These are the settings Solar-Log asks for in its configuration screen in Gladys.
| Setting | Type | Required | Description |
|---|---|---|---|
| Getting started | section | No | The integration reads your Solar-Log on your local network, through its open JSON interface. In the Solar-Log web page, open Configuration > System > Access control and turn on "Open JSON interface", then enter its address below. No cloud account is needed. |
| Solar-Log address | string | Yes | IP address or host name of the Solar-Log on your network. Give it a fixed address in your router. |
| User password (optional) | secret | No | Only if the "user" access level of the Solar-Log is protected by a password. It unlocks the per-inverter and battery data. |
| Refresh interval (s) | number | No | How often the Solar-Log is read, in seconds (30 minimum). |
| Production threshold (W) | number | No | Production above which the "Production started" trigger fires. "Production stopped" fires below half of it. |
| Surplus threshold (W) | number | No | Surplus (production minus consumption) from which the "Surplus available" trigger fires. Needs a consumption meter on the Solar-Log. |
| Surplus margin (W) | number | No | "Surplus ended" fires only when the surplus drops this far below the threshold, so a passing cloud does not start and stop your appliances. |
| One device per inverter | boolean | No | Also create a device with the live power of each inverter connected to the Solar-Log. |
How to install Solar-Log in Gladys
- In Gladys, open Integrations: Solar-Log appears in the catalog, next to the native integrations, with a community badge.
- Click Install. Gladys pulls the Docker image (
ghcr.io/prohand/gladys-solarlog:0.0.1), starts it in a sandbox isolated from the core, and generates the integration's interface (devices, discovery and configuration). - Open the Configuration screen of the integration, fill in the settings, and save.
- You can also install it directly from its repository URL: https://github.com/prohand/gladys-solarlog.
Solar-Log requires Gladys >=5.3.0. The catalog inside Gladys refreshes every hour, so a new version becomes available at most one hour after its release.
Not running Gladys yet? It is free and open source: follow the installation guide to get started.
About external integrations
Solar-Log is an external integration: a community integration packaged as a Docker container and published on GitHub, that Gladys installs in one click and runs in a sandbox isolated from its core. It is published and maintained by prohand, not by the Gladys core team.
- Browse all integrations, native and community
- Build and publish your own external integration
- Source code on GitHub — source of this documentation