Siemens S7 smart home integration, free and open source

Read and write the variables of a Siemens S7 PLC (S7-300 to S7-1500, LOGO!) on the local network.
Read and write the variables of a Siemens PLC from Gladys, on your local network: S7-300, S7-400, S7-1200, S7-1500, ET 200SP CPUs and LOGO! 0BA7 / 0BA8. The integration speaks the S7 protocol (S7comm over ISO-on-TCP, port 102), the one Siemens HMIs and engineering tools use.
Developed without the hardware: feedback welcome. It was tested against the Snap7 S7 server, not against a real PLC. Tell us on the Gladys forum how it behaves with yours.
What you getβ
- One Gladys device for the PLC, one feature per variable you declare: a temperature, a counter, a bit of a DB, an input, an output, a LOGO! V memory word.
- Values read at the pace you choose (1 second to 1 minute), all variables at once in as few requests as the PLC allows; only the changes are sent to Gladys.
- On demand, writing a value to the variables you declare writable: a switch or a setpoint on the dashboard, an action, a scene.
- Scene triggers when the PLC is lost or back, or when an address becomes unreadable, and a dashboard widget with the health of the link.
Requirementsβ
- Gladys 5.1 or later.
- The PLC on the same network as Gladys, port 102 reachable, with a fixed IP address.
- For an S7-1200 or S7-1500: PUT/GET access allowed (see below).
- For a LOGO!: a server connection set in LOGO!Soft Comfort (see below).
Configurationβ
Install the integration (Integrations β Install from GitHub, address
https://github.com/guim31/gladys-siemens-s7), open its Configuration
tab, fill the fields, save, then add the PLC from the Discovery tab.
PLCβ
- PLC IP address: the address of the CPU (or of its Ethernet module).
- TCP port: 102, always, unless a gateway forwards another port.
- PLC type: sets how the CPU is reached. S7-1200, S7-1500 and ET 200SP: rack 0, slot 1. S7-300: rack 0, slot 2. LOGO!: the TSAPs below. Other: the Rack and Slot fields (an S7-400 CPU is often in slot 3; check the hardware configuration of your project).
Gladys identifies the PLC by its address and port: changing the address creates a new device.
S7-1200 and S7-1500: PUT/GETβ
These CPUs refuse outside reads until you allow them, in TIA Portal:
- CPU properties β Protection & Security β Connection mechanisms: tick Permit access with PUT/GET communication from remote partner.
- For every DB you want to read: block properties β Attributes, untick Optimized block access, then compile. An optimized DB has no fixed addresses: its variables cannot be read by address.
- Download the project to the CPU.
Without step 1, the Configuration screen says that the CPU refuses the reads.
LOGO!β
In LOGO!Soft Comfort, Tools β Ethernet Connections, add a Server connection (S7 connection), tick Accept all connection requests, and note the two TSAPs:
- Local TSAP of the LOGO! (usually
02.00): the field LOGO! local TSAP (server side). - Remote TSAP (usually
01.00): the field LOGO! remote TSAP (client side).
Download the program to the LOGO!. Its variable memory (VM) is DB1 for the S7
protocol: VW10 is the word at VM address 10. Map the values you want to see
(analog inputs, flags, counters) to VM in Tools β Parameter VM Mapping
(LOGO! 8).
Variablesβ
The Variables field holds the variables to read, separated by semicolons:
Name: address kind write option=value
Only the address is required. Examples:
Boiler: DB1,REAL0 temperature; Pump: Q0.1 switch; Setpoint: DB1,REAL4 setpoint min=5 max=30; Level: VW10 scale=0.1 unit=%
- Name: the name of the feature in Gladys (40 characters at most). Without
Name:, the variable is named after its address. - Kind: what the value is, which sets its icon and unit in Gladys:
temperature,humidity,pressure,power,energy(an index, in kWh in Gladys),production,solar_power,grid_power,voltage,current,battery,volume,duration,value(a plain number, the default),binary(an on/off state, the default for a bit),switch(an on/off you can change),setpoint(a temperature you can change). - write: the variable may be written from Gladys (see Writing).
- Options:
scale=andoffset=(value shown = raw Γ scale + offset, soscale=0.1turns 215 into 21.5),unit=(Β°C, %, W, kWh, Wh, V, A, bar, L, m3, s, min, h...),min=andmax=(the range shown, and the limits of a write),precision=(decimals kept).
Up to 100 variables. Check the configuration lists the mistakes entry by entry.
Addressesβ
| Address | Type | Range |
|---|---|---|
DB1,X0.1 or DB1.DBX0.1 | bit | 0 / 1 |
DB1,BYTE2 or DB1.DBB2 | BYTE | 0 to 255 |
DB1,WORD4 or DB1.DBW4 | WORD (unsigned) | 0 to 65535 |
DB1,INT6 | INT (signed) | -32768 to 32767 |
DB1,DWORD8 or DB1.DBD8 | DWORD | 0 to 4294967295 |
DB1,DINT8 | DINT | -2147483648 to 2147483647 |
DB1,REAL12 | REAL | 32-bit floating point |
DB1,LREAL16 | LREAL | 64-bit (S7-1200/1500 only) |
M0.1, I0.0 (E0.0), Q0.1 (A0.1) | bit | 0 / 1 |
MB10, MW10, MI10, MD10, MDI10, MR10 | BYTE, WORD, INT, DWORD, DINT, REAL | |
V10.0, VB10, VW10, VI10, VD10, VR10 | LOGO! VM (DB1) |
The address sets the type: DB1.DBD8 is a DWORD, read as an integer. For a
REAL, write DB1,REAL8 (or MR8, VR8). A WORD is unsigned: for a negative
value stored as INT, write DB1,INT6 or MI10.
Writingβ
Writing is off until you turn on Allow writing. Even then, only the
variables declared write (or of kind switch or setpoint) can be changed:
- a
switchshows an on/off toggle on the dashboard, asetpointa setpoint control; other writable variables are written by the Write a value action or the scene action; - a bit is written alone: the other bits of its byte stay as they are;
- the value is checked against
min/max(by default, the range of the kind: Β±1,000,000 forvalue, 0 to 100 forsetpoint) and the range of the type before being sent; a number like1,000is refused as ambiguous; then read back, so the dashboard shows what the PLC really holds.
Writing a wrong variable can stop or damage an installation. Declare writable only what Gladys must change, and keep safety functions in the PLC program. On purpose, nothing is exposed as a switch or a thermostat to voice assistants.
Actionsβ
On the Configuration screen:
- Check the configuration: whether the PLC answers, how many variables it reads, and the mistakes entry by entry.
- Read an address: reads any address once, declared or not, to find the right one before declaring it.
- Write a value: writes to a declared writable variable, by name or address.
Scenesβ
- Triggers (Gladys 5.1 or later): The PLC is lost (with the reason), The PLC is back, A PLC variable becomes unreadable (a DB deleted or shortened by a new PLC program, with the name of the variable). The values themselves trigger scenes as any Gladys device does.
- Action: Write a PLC variable, with a variable (name or address) and a value.
Dashboardβ
The Siemens PLC widget shows the first six values of the PLC and the health of the link: connected or not, how many variables are readable, the time of the last reading and how long it took. Each block can be hidden in the widget settings.
Siemens S7, Modbus or OPC UA?β
- This integration reads the memory of the PLC by address, with nothing to program on the PLC side (except PUT/GET on S7-1200/1500). The simplest way for a LOGO!, an S7-300/400 or an S7-1200.
- Modbus: a LOGO! 8 (from FS4) and some S7-1200 programs also speak Modbus TCP. Choose it when the PLC is already set up as a Modbus server.
- OPC UA: an S7-1500 (and an S7-1200 from firmware 4.4) has an OPC UA server, with named variables, optimized DBs and security. Choose it when you can turn that server on.
Limitsβ
- One PLC per installation of the integration.
- Numbers and bits only: no STRING, DATE_AND_TIME, arrays, timers or counters
(
T,C). - Optimized DBs of S7-1200/1500 cannot be read by address (see PUT/GET).
- S7-1200/1500 with a protection level that forbids PUT/GET, and S7-200 (PPI) are not supported.
- No secure connection: the S7 protocol has none; keep the PLC on a trusted network.
- Gladys accepts 300 values a minute: with many variables, the values are sent less often than they are read.
Troubleshootingβ
- The PLC does not answer on port 102: check the address, that Gladys and the PLC are on the same network, and that no firewall blocks port 102.
- The PLC refuses the connection: wrong PLC type, rack/slot or TSAP. For a LOGO!, check the server connection in LOGO!Soft Comfort and that the program was downloaded.
- The CPU refuses the reads: allow PUT/GET (see above).
- Address out of range: the DB is shorter than the address, it is optimized, or the program does not have it.
- The logs of the integration (Gladys β Integrations β Siemens S7) say more
with the environment variable
LOG_LEVEL=debug.
Creditsβ
The S7 client of this integration is written from the public descriptions of the protocol: Snap7 by Davide Nardella, nodes7 (MIT) by plcpeople, and the s7comm dissector of Wireshark. It was tested against the Snap7 server through python-snap7 (MIT).
Siemens, SIMATIC, S7 and LOGO! are trademarks of Siemens AG. This integration is not affiliated with Siemens.
Configuration settingsβ
These are the settings Siemens S7 asks for in its configuration screen in Gladys.
| Setting | Type | Required | Description |
|---|---|---|---|
| Getting started | section | No | Enter the IP address of the PLC and its type, declare the variables to read (DB1,REAL0, M0.1, VW10...), save, and add the PLC from the Discovery tab: each variable becomes a feature. S7-1200/1500: allow PUT/GET access first. |
| Language of the messages | select | No | Used for the texts given to the scenes and the action messages. |
| PLC | section | No | Give the PLC a fixed IP address: Gladys identifies it by its address and port. |
| PLC IP address | string | No | |
| TCP port | number | No | 102 for every S7 PLC; change it only behind a gateway. |
| PLC type | select | No | Sets how the CPU is reached (rack and slot, or TSAP for a LOGO!). |
| Rack | number | No | Used with the type Other only. |
| Slot | number | No | Used with the type Other only. S7-400: usually 3. |
| LOGO! remote TSAP (client side) | string | No | LOGO! only: the "Remote TSAP" of the server connection in LOGO!Soft Comfort. |
| LOGO! local TSAP (server side) | string | No | LOGO! only: the "Local TSAP" of the server connection in LOGO!Soft Comfort. |
| Variables | section | No | Up to 100 variables. Writing a wrong variable can stop or damage an installation: declare "write" only what Gladys must change. |
| Variables | string | No | Entries separated by semicolons: name: address, then kind, write and options. Addresses: DB1,REAL0 DB1,INT2 DB1,X4.0 M0.1 MW10 MD12 I0.0 Q0.1 VW10. Kinds: temperature, humidity, pressure, power, energy, production, solar_power, grid_power, voltage, current, battery, volume, duration, value, binary, switch, setpoint. Options: scale= offset= unit= min= max= precision=. |
| Reading interval | select | No | How often the PLC is read. Gladys accepts 300 values a minute: with many variables, the values are sent less often. |
| Allow writing | boolean | No | Off by default. When on, only the variables declared "write" (or switch, setpoint) can be changed from Gladys. |
How to install Siemens S7 in Gladysβ
- In Gladys, open Integrations: Siemens S7 appears in the catalog, next to the native integrations, with a community badge.
- Click Install. Gladys pulls the Docker image (
ghcr.io/guim31/gladys-siemens-s7:1.0.0), starts it in a sandbox isolated from the core, and generates the integration's interface (devices, discovery and configuration). - Open the Configuration screen of the integration, fill in the settings, and save.
- You can also install it directly from its repository URL: https://github.com/guim31/gladys-siemens-s7.
Siemens S7 requires Gladys >=5.1.0. The catalog inside Gladys refreshes every hour, so a new version becomes available at most one hour after its release.
Not running Gladys yet? It is free and open source: follow the installation guide to get started.
About external integrationsβ
Siemens S7 is an external integration: a community integration packaged as a Docker container and published on GitHub, that Gladys installs in one click and runs in a sandbox isolated from its core. It is published and maintained by guim31, not by the Gladys core team.
- Browse all integrations, native and community
- Build and publish your own external integration
- Source code on GitHub β source of this documentation