InComfort (Intergas) smart home integration, free and open source

InComfort (Intergas) integration for Gladys Assistant

Intergas boilers through the local Lan2RF gateway: temperatures, pressure, status, rooms.

Your Intergas boilers in Gladys, through the local Lan2RF gateway (InComfort / InTouch) on your network, without any cloud:

  • each boiler bound to the gateway becomes a Gladys device: heating water temperature, pressure (bar), hot water temperature, burner on, pump on, hot water function, fault (lockout), and in words its status (standby, central heating, hot water…) and its fault (E… code and label);
  • each room thermostat (two at most per boiler) becomes a device with the room temperature, the setpoint and heating (burner and pump on).

This integration has never been tested on a real gateway. This first version was written from the incomfort-client library and the incomfort integration of Home Assistant, and tested only against a fake gateway. Tell on the Gladys forum what works and what does not.

Unofficial integration, not affiliated with Intergas.

Configuration​

  • Gateway address: its IP address on your network (192.168.1.20); a port may follow (192.168.1.20:80). Prefer the IP address: a .local (mDNS) name does not resolve inside the container of the integration. Give it a fixed address in your router. The gateway only speaks plain http: an https:// address is refused with a clear message.
  • User name and password: leave them empty for an older gateway. Newer gateways ask for those printed on their label or in their manual; Gladys then uses the /protect/ pages of the gateway. The password is kept by Gladys in its database, never shown again, sent only to the gateway, in the HTTP authentication header (never in an address, never in a log). Beware: the gateway has no https, so the user name and password cross your local network in clear, at every reading.
  • Allow changing the room setpoint: off by default (see Command).
  • Language of the devices: French (default) or English, for the device names and the status and fault texts.

Then open the Discovery tab and create the boilers and thermostats to follow. The Test the connection button reads the gateway right away and lists what it sees.

Command​

  • Only the room setpoint can be changed, and only once Allow changing the room setpoint is ticked. Once ticked, the dashboard, the scenes, the voice assistants (Siri / HomeKit...) and the Thermostat service of Gladys can change the setpoint, from 5 to 30 °C. Nothing turns the boiler on or off and nothing touches the hot water: no feature is a switch, so "turn everything off" cannot act on the boiler.
  • The setpoint goes from 5 to 30 °C (the bounds of the gateway), to a tenth of a degree: a value outside is refused, never clamped.
  • Just before acting, Gladys reads the boiler list and the boiler again: when the reading fails, the boiler is no longer bound or the thermostat no longer answers, nothing is sent; when the thermostat is already at this setpoint (and no other remote setpoint is pending), nothing is sent either. When the command cannot be checked within 3.5 s, nothing is sent and Gladys shows a failure (never an action after a failure was shown). Once sent, Gladys answers at most 4.3 s after your command; the setpoint shown follows the answer of the gateway.
  • Commands run one after the other (one gateway).
  • The setpoint shown is, like in Home Assistant, the setpoint sent remotely when there is one, else the thermostat's own. The thermostat gets the setpoint by radio: it may take a moment to show there. Some older thermostats keep the remote setpoint even after a change by hand: the setpoint shown in Gladys may then stay the old one.

Refresh and limits​

  • The gateway is read every 30 seconds: the boiler list, then each boiler (its thermostats come with it). States are up to 30 seconds late. Only the values that change are sent to Gladys (and each one at least every 30 minutes).
  • A boiler that does not answer makes only its own devices unreachable; the others go on.
  • The water temperatures (heating water, hot water) are probes: Gladys keeps them out of the temperature of the room the boiler is in.
  • A Lan2RF gateway handles 8 boilers at most, 2 room thermostats per boiler. A thermostat shows up only once the gateway gives a valid temperature for it.
  • Boilers are recognised by their serial number (the one the gateway lists), not by their position in the list: a boiler that moves keeps its device, its history and its scenes.

Connection problems​

  • Gateway unreachable: every device shows unreachable; retried after 30 s, then less and less often up to every 10 min (never faster than the normal reading).
  • Credentials asked or refused (HTTP 401): Gladys does not try again by itself, not even after a reconnection to Gladys. Fix the user name and password and save, or press Test the connection. A restart of the integration makes one new try.
  • HTTP 404 with a user name: the gateway is an older one without protected pages: clear the user name and the password.
  • Gateway overloaded (HTTP 429): every request stops for 1 minute to 6 hours; saving the configuration or pressing Test the connection lifts the pause.
  • The logs hold neither the password nor the text of the gateway's answers, only codes (HTTP 500, no connection…).

Limits​

  • One gateway per integration.
  • No hot water command nor boiler mode: the gateway offers none, and hot water is read only on purpose.
  • Neither the radio signal strength nor the node number are published.
  • Never tested on a real gateway, nor with real credentials.

Configuration settings​

These are the settings InComfort (Intergas) asks for in its configuration screen in Gladys.

SettingTypeRequiredDescription
How it workssectionNoGladys reads your Intergas boilers every 30 seconds through the Lan2RF (InComfort) gateway, on your local network, without any cloud. Each boiler becomes a Gladys device (Discovery tab): heating water temperature, pressure, hot water temperature, burner, pump, hot water, fault, status; each room thermostat becomes a device with its temperature and setpoint. Unofficial integration, not affiliated with Intergas. Never tested on a real gateway: see the documentation.
Gateway addressstringYesThe IP address (or name) of the Lan2RF gateway on your network. Give it a fixed address in your router. Plain http: the gateway has no https.
Credentials (newer gateways)sectionNoOlder gateways answer without credentials: leave both fields empty. Newer ones ask for a user name and password (those of the gateway, see its label or manual). They go to the gateway in an HTTP header, in clear on your local network (the gateway has no https).
User name (optional)stringNo
Password (optional)secretNoKept by Gladys in its database, never shown again, sent only to the gateway.
OptionssectionNoBy default Gladys only reads. Once the option below is ticked, the dashboard, the scenes, the voice assistants (Siri / HomeKit...) and the Thermostat service of Gladys can change the setpoint of the room thermostats, from 5 to 30 °C. Nothing ever turns the boiler on or off, and hot water is never commanded.
Allow changing the room setpointbooleanNo
Language of the devicesselectNoNames of the devices and features, status and fault texts.

How to install InComfort (Intergas) in Gladys​

  1. In Gladys, open Integrations: InComfort (Intergas) appears in the catalog, next to the native integrations, with a community badge.
  2. Click Install. Gladys pulls the Docker image (ghcr.io/lm1lc3n7/gladys-incomfort:0.1.1), starts it in a sandbox isolated from the core, and generates the integration's interface (devices, discovery and configuration).
  3. Open the Configuration screen of the integration, fill in the settings, and save.
  4. You can also install it directly from its repository URL: https://github.com/LM1LC3N7/gladys-incomfort.

InComfort (Intergas) requires Gladys >=5.1.0. The catalog inside Gladys refreshes every hour, so a new version becomes available at most one hour after its release.

Not running Gladys yet? It is free and open source: follow the installation guide to get started.

About external integrations​

InComfort (Intergas) is an external integration: a community integration packaged as a Docker container and published on GitHub, that Gladys installs in one click and runs in a sandbox isolated from its core. It is published and maintained by LM1LC3N7, not by the Gladys core team.