Grid Frequency integration for Gladys Assistant

Real-time frequency of the European power grids: continental, Nordic and Great Britain.

The frequency of the European power grids in real time: continental Europe, the Nordic area and Great Britain. Every grid in Europe runs at 50 Hz; the frequency drops a little when consumption exceeds production and rises when production exceeds consumption. It is the pulse of the grid, the same value in every socket of a synchronous area. Read from open sources, without an account or a key: netzfrequenzmessung.de and netzfrequenz.info (continental Europe), Statnett (Nordic area) and Elexon (Great Britain). This integration is not affiliated with any of them.

Overview​

For every zone you follow, the integration adds a device with:

  • the frequency, in Hz, to the thousandth;
  • the deviation from 50 Hz, in mHz (−38 means 49.962 Hz);
  • the grid state: 0 normal, 1 notable deviation, 2 strong deviation (see "Grid states" below);
  • the time of the measurement and the source that gave it.

On top of that: a dashboard widget with the last hour, and two scene triggers, "Frequency beyond the threshold" and "Frequency back to normal". What for: watching the grid as a hobby, explaining it to the family, or postponing a big consumption while the grid is short.

Requirements​

  • Gladys Assistant 5.2.0 or later.
  • Internet access from Gladys. No account, no key.

Installation​

In Gladys, Integrations → Install from GitHub, address https://github.com/guim31/gladys-grid-frequency. Then open the Configuration tab of the integration, choose your zones and save. The devices appear in the Discovery tab: add them.

Configuration​

  • Language of the names: language of the device and feature names (fixed when a device is added) and of the texts sent to scenes. French by default.
  • Continental Europe, Nordic area, Great Britain: one device per zone ticked. Continental Europe goes from Portugal to Poland and Greece, France and Germany included. The Nordic area is Norway, Sweden, Finland and eastern Denmark. Western Denmark is part of continental Europe; Ireland and the Baltic states are not covered.
  • Reading interval: 10, 15, 30 (default) or 60 seconds. Each reading can publish new states, kept in the history of Gladys.
  • Alert threshold: the deviation from 50 Hz, in mHz, that fires the scene trigger: ±50, ±100 (default), ±150, ±200, ±300 or ±500 mHz.

Test the sources button​

Reads every source of every zone, the fallback ones too, and says what each answered. The message is red when a zone has no source answering.

Devices​

Grid frequency (one per zone)​

FeatureValues
Frequency (Hz)47.5 to 52.5, three decimals
Deviation from 50 Hz (mHz)signed, −500 to +500 shown on a gauge
Grid state (0 to 2)0 normal, 1 notable, 2 strong
Measurement time"16:19:00", in the time zone of Gladys
Sourcenetzfrequenzmessung.de, netzfrequenz.info, …

Gladys has no hertz unit: the unit is in the name of the feature. The states are published only when they change, and at least every six hours.

Grid states​

The thresholds come from the European rules for grid operation (SOGL, EU regulation 2017/1485) and from the British grid code:

ZoneNormalNotableStrong
Continental Europeup to 50 mHz50 to 200 mHzover 200 mHz
Nordic areaup to 100 mHz100 to 500 mHzover 500 mHz
Great Britainup to 200 mHz200 to 500 mHzover 500 mHz

"Normal" is the standard frequency range of the area. Beyond it, the reserves are at work; beyond "strong", the primary reserve of the continent is fully deployed (or, in Great Britain, the statutory limit is crossed). For reference on the continent: within ±10 to ±20 mHz the reserves do not even react; 49.8 Hz triggers the emergency plans of the operators; 49 Hz starts automatic load shedding. Great Britain and the Nordic area, smaller grids, move more: ±100 mHz is an everyday value there.

Widget​

Grid frequency: the name of the zone's device, the frequency and the deviation (green, orange or red after the grid state), the frequency of the last hour from the history of Gladys (once the device is added), the grid state, the source and the time of the measurement. Settings: the zone, and two switches to hide the chart or the state and source.

Scenes​

Frequency beyond the threshold (trigger)​

The deviation of a zone goes beyond the alert threshold of the configuration. Once per excursion. Filters: the zone, the direction (under 50 Hz: shortage; over 50 Hz: surplus). Variables: direction (low, high), frequency (Hz), deviation (mHz), threshold (mHz), grid state as a word, zone.

Frequency back to normal (trigger)​

After an excursion, the deviation falls back under 80 % of the threshold (the margin avoids a burst of events when the value hovers at the threshold). Filter: the zone. Variables: frequency, deviation, peak deviation (mHz), duration of the excursion (seconds), zone.

Scene examples​

  • "Frequency beyond the threshold", direction under 50 Hz → turn off the water heater; "Frequency back to normal" → turn it back on.
  • "Frequency beyond the threshold" → send a message with the frequency and the deviation, taken from the variables of the trigger.
  • A device-value trigger on "Grid state" equal to 2 → notification.

Sources and terms of use​

ZoneSourcePace
Continental Europenetzfrequenzmessung.de, interface for private usevalue every 3 s
Continental Europenetzfrequenz.info, fallbackvalue every second
Nordic areaStatnett, operational datavalue every 10 s
Great BritainElexon BMRS, system frequency (FREQ)every 15 s, ~2 min late

The second continental source is asked only when the first fails, answers something implausible or a value older than a minute. In normal operation, the integration asks each source at most once per interval (10 s at least), far below the "once a second" netzfrequenzmessung.de allows. Its interface is meant for private use: a home automation system is one. Elexon data is published under the Elexon BMRS data licence.

Limits​

  • The continental value is measured in Germany: it is the same in France, Spain or Italy (one synchronous grid), up to a few mHz during fast events.
  • A reading every 10 seconds at best: a short dip of one or two seconds can be missed.
  • Great Britain is about two minutes late: no trigger there for a fast reaction.
  • One source per zone for the Nordic area and Great Britain: no fallback.
  • The open sources give no guarantee of service.

Troubleshooting​

  • "No source answers" in the configuration screen: use the "Test the sources" button; the message names each source and its error. A source down is usually back within minutes.
  • No state on a device: check that it is added (Discovery tab).
  • Too many events: raise the alert threshold; ±100 mHz is rare on the continent but common in Great Britain.
  • For details: LOG_LEVEL=debug in the logs of the integration.

Credits​

Data: netzfrequenzmessung.de, netzfrequenz.info, Statnett and Elexon BMRS. Integration by guim31, Apache-2.0.

Configuration settings​

These are the settings Grid Frequency asks for in its configuration screen in Gladys.

SettingTypeRequiredDescription
Open sources, no accountsectionNoThe frequency tells the balance between production and consumption, at 50 Hz in Europe. Read from netzfrequenzmessung.de and netzfrequenz.info (continental), Statnett (Nordic) and Elexon (Great Britain). Not affiliated with them.
Language of the namesselectNoLanguage of the device and feature names (fixed when a device is added) and of the texts sent to scenes.
Continental EuropebooleanNoFrom Portugal to Poland and Greece, France and Germany included: one device.
Nordic areabooleanNoNorway, Sweden, Finland and eastern Denmark: one device.
Great BritainbooleanNoEngland, Scotland and Wales: one device. The values arrive about two minutes late.
Reading intervalselectNoHow often each zone is read. Every reading can change the states: 30 s is a good balance.
Alert thresholdselectNoDeviation from 50 Hz that fires the scene trigger. 100 mHz is rare on the continent, usual in Great Britain.

How to install Grid Frequency in Gladys​

  1. In Gladys, open Integrations: Grid Frequency appears in the catalog, next to the native integrations, with a community badge.
  2. Click Install. Gladys pulls the Docker image (ghcr.io/guim31/gladys-grid-frequency:1.0.0), starts it in a sandbox isolated from the core, and generates the integration's interface (devices, discovery and configuration).
  3. Open the Configuration screen of the integration, fill in the settings, and save.
  4. You can also install it directly from its repository URL: https://github.com/guim31/gladys-grid-frequency.

Grid Frequency requires Gladys >=5.2.0. The catalog inside Gladys refreshes every hour, so a new version becomes available at most one hour after its release.

Not running Gladys yet? It is free and open source: follow the installation guide to get started.

About external integrations​

Grid Frequency is an external integration: a community integration packaged as a Docker container and published on GitHub, that Gladys installs in one click and runs in a sandbox isolated from its core. It is published and maintained by guim31, not by the Gladys core team.

Subscribe to the Gladys Assistant newsletter