Skip to main content

EnOcean smart home integration, free and open source

EnOcean integration for Gladys Assistant

EnOcean sensors, switches and actuators through a USB 300 gateway shared by ser2net.

This integration connects Gladys to EnOcean devices — battery-free switches, temperature, humidity, CO2, occupancy and light sensors, door contacts, window handles, relays and dimmers — through an ESP3 gateway: the EnOcean USB 300 stick, a TCM 310 module, or any gateway built on them.

1. What you need​

  • Gladys 5.3 or later.
  • An ESP3 gateway (USB 300, USB 310, TCM 310 board...), for your country's frequency: 868 MHz in Europe, 902 MHz in North America.
  • A machine on your network to plug it into: the Gladys host itself, or a Raspberry Pi closer to the devices.
  • ser2net on that machine.

Why ser2net? The integration runs in a sandboxed container that cannot see USB devices. ser2net shares the serial port of the stick as a TCP port, and the integration connects to it. It also lets you put the stick where reception is best, away from the Gladys server.

2. Share the stick with ser2net​

Install it (apt install ser2net on Debian, Ubuntu and Raspberry Pi OS), then find the stable name of the stick:

ls -l /dev/serial/by-id/

ser2net 4 (/etc/ser2net.yaml):

connection: &enocean
accepter: tcp,9999
enable: on
options:
kickolduser: true
connector: serialdev,/dev/serial/by-id/usb-EnOcean_GmbH_EnOcean_USB_300_DC_XXXXXXXX-if00-port0,57600n81,local

ser2net 3 (/etc/ser2net.conf):

9999:raw:0:/dev/serial/by-id/usb-EnOcean_GmbH_EnOcean_USB_300_DC_XXXXXXXX-if00-port0:57600 8DATABITS NONE 1STOPBIT

Then systemctl restart ser2net. Keep in mind:

  • 57600 bauds, 8N1, raw mode (no telnet): ESP3 is binary.
  • kickolduser: true: the port takes one client. When the integration reconnects (update, Gladys restart), the old session must give way.
  • The port has no password. Open it to the Gladys host only: bind it to one address (accepter: tcp,192.168.1.50,9999) and/or filter it with your firewall.

3. Configure the integration​

In Integrations → EnOcean → Configuration:

FieldWhat to fill in
Gateway hostIP address of the machine running ser2net. Not 127.0.0.1 (own container).
Gateway TCP portThe port of ser2net (9999 above).
DevicesYour devices, see below.
Report unknown devicesFires the "unknown device heard" scene trigger. Turn it off if neighbours flood.
Detailed logs (debug)Logs every telegram heard. For troubleshooting only.

Save, then press Test the connection: it shows the module, its base id and how many telegrams were heard.

4. Declare your devices​

EnOcean has no discovery: a sensor says "I am 0194E3B2", never what it measures. Each device is declared once, as a JSON list in the Devices field:

[
{ "id": "0194E3B2", "eep": "A5-02-05", "name": "Living room" },
{ "id": "FEF1A2B3", "eep": "F6-02-01", "name": "Entrance switch" },
{ "id": "01A1B2C3", "eep": "F6-10-00", "name": "Kitchen window" },
{ "eep": "A5-38-08", "channel": 1, "name": "Kitchen dimmer", "dimmable": true },
{ "eep": "F6-02-01", "channel": 2, "rocker": "a", "name": "Garden relay" },
{ "id": "05123456", "eep": "D2-01-12", "channel": 3, "name": "Plug" }
]
KeyMeaning
idThe EnOcean id of the device, 8 hex digits (printed on it). Needed for everything it sends.
eepIts profile (EEP), see the table below. Printed in its manual.
nameThe name shown in Gladys.
channelActuators only: the gateway channel (0-127) Gladys sends from. One per actuator or group.
dimmabletrue for a dimmer (A5-38-08, D2-01): adds a brightness feature.
rockerVirtual rocker relays: a (default) or b, the side the relay learned.
ioD2-01 with several outputs: the output number (0 = first).

You do not have to read the ids yourself: open the learn mode, press the button of the device, then press Devices heard. It prints the lines to paste, with the profile when the device sends it.

After saving, the devices appear in Discovery: add them to Gladys there.

Ids are forever. Gladys keys the history, the scenes and the dashboards on the id (sensors, D2-01) or on the channel (other actuators). Changing them creates a new device.

5. Supported profiles​

EEPDeviceIn Gladys
A5-02-01 to 1B, 20, 30Temperature sensorsTemperature
A5-04-01, A5-04-02Temperature and humidity sensorsTemperature, humidity
A5-06-01, A5-06-02Light sensorsIlluminance (lx)
A5-07-01, 02, 03Occupancy sensors (03: with light)Motion (+ illuminance)
A5-09-04CO2 sensorsCO2, temperature, humidity
D5-00-01Door and window contactsOpening sensor (1 = closed)
F6-10-00Window handles (Hoppe...)Opening sensor + "handle turned" scene trigger
F6-02-01, F6-02-02 + idRocker switches (PTM 215, Eltako FT55...)4 buttons (click / long click) + scene trigger
F6-02-01 + channelRelays that learned a rocker (Eltako FSR...)On/off switch
A5-38-08 + channelEltako central command relays and dimmersOn/off (+ brightness)
D2-01-00 to 14Electronic switches and dimmers (NodOn...)On/off (+ brightness)

The buttons of a rocker switch are named after the EEP: ao / ai for the upper / lower side of rocker A, bo / bi for rocker B. A press under one second is a click, a longer one a long click.

6. Pair an actuator​

Actuators are driven from a channel of the gateway: Gladys sends from the gateway base id + the channel. The actuator must learn that sender once.

  • Relay that learns a rocker (F6-02-01 + channel) and Eltako central command (A5-38-08): turn the actuator to its learn position (LRN), then in Gladys press Pair an actuator and pick it. Turn it back to its operating position. Add the actuator id to the entry if you want Gladys to follow its confirmations (Eltako sends them).
  • D2-01 (NodOn...): they pair from their own side. Press Open the learn mode in Gladys (or the button of the widget), then the pairing button of the device: Gladys answers its request from channel 0, or from the channel already declared for its id. Declare it with its id and that channel (0 when it was not declared yet).

The base id is burned into the stick. Keep the stick: with another one, the actuators must learn the new sender again.

7. Scenes​

Triggers:

  • An EnOcean switch is pressed: filter on the switch, the button and the press (short, long). Variables: device_name, button, press, duration_ms.
  • A window handle is turned: filter on the handle and the position (closed, open, tilted). Variables: device_name, position.
  • An unknown EnOcean device is heard: once an hour per device at most. Variables: sender_id, eep, rorg, dbm, teach_in.
  • The EnOcean gateway is lost: the TCP connection dropped (the integration keeps retrying). Variables: address, reason.

Actions:

  • Press a virtual EnOcean switch: sends a rocker press from a channel, like a real switch. Every actuator that learned it reacts — handy for groups. Output: sent.
  • Send an EnOcean teach-in: the teach-in telegram of a declared actuator. Output: sent.

8. Dashboard widget​

The EnOcean radio widget shows the gateway state, its base id and module, the learn mode, and the last devices heard (with their signal), the unknown ones flagged. Its button opens the learn mode for 60 seconds.

9. Troubleshooting​

  • "Gateway unreachable": check from the Gladys host that the port answers (nc -vz 192.168.1.50 9999), that ser2net runs, and that no other program (another home automation box) holds the port.
  • Connected but nothing heard: wrong baud rate (57600), telnet mode instead of raw, or a stick of the wrong frequency.
  • A device is heard but nothing changes in Gladys: wrong eep in its entry, or the device was not added from Discovery. Turn on the detailed logs: each telegram is logged with its sender and its bytes.
  • An actuator does not react: it did not learn the channel (pair it again), or Test the connection says the base id is unknown.
  • Radio range: concrete and metal walls block 868 MHz. Move the stick (a USB extension cable helps) or add an EnOcean repeater.

Configuration settings​

These are the settings EnOcean asks for in its configuration screen in Gladys.

SettingTypeRequiredDescription
Getting startedsectionNoThe integration runs in a container that cannot see USB devices: plug your EnOcean USB 300 (or any ESP3 gateway) into a machine of your network and share it with ser2net as a raw TCP port at 57600 bauds. Then fill in its address below and declare your devices.
Gateway hoststringYesIP address or name of the machine running ser2net. Not 127.0.0.1: the integration runs in its own container.
Gateway TCP portnumberYesThe port ser2net listens on for the EnOcean module (raw mode, no telnet).
DevicesstringNoYour EnOcean devices as a JSON list: one entry per device with its id (8 hex digits), its profile (EEP, e.g. A5-02-05) and a name. Actuators also get a channel (0-127). The "Devices heard" button writes the lines for you. See the documentation.
Report unknown devicesbooleanNoFire the "An unknown EnOcean device is heard" scene trigger, at most once an hour per device. Turn it off if your neighbours' sensors are heard all day.
Detailed logs (debug)booleanNoLog every telegram heard, with its sender, its bytes and its signal. Turn it on to find out why a device does not show up, and off again once you know.

How to install EnOcean in Gladys​

  1. In Gladys, open Integrations: EnOcean appears in the catalog, next to the native integrations, with a community badge.
  2. Click Install. Gladys pulls the Docker image (ghcr.io/prohand/gladys-enocean:1.0.1), starts it in a sandbox isolated from the core, and generates the integration's interface (devices, discovery and configuration).
  3. Open the Configuration screen of the integration, fill in the settings, and save.
  4. You can also install it directly from its repository URL: https://github.com/prohand/gladys-enocean.

EnOcean requires Gladys >=5.3.0. The catalog inside Gladys refreshes every hour, so a new version becomes available at most one hour after its release.

Not running Gladys yet? It is free and open source: follow the installation guide to get started.

About external integrations​

EnOcean is an external integration: a community integration packaged as a Docker container and published on GitHub, that Gladys installs in one click and runs in a sandbox isolated from its core. It is published and maintained by prohand, not by the Gladys core team.

Subscribe to the Gladys Assistant newsletter

A few emails per month about new releases and project news. Sent by Pierre-Gilles Leymarie, founder of the project. Unsubscribe anytime 🙂