Zum Hauptinhalt springen

Atrea Smart-Home-Integration, kostenlos und Open Source

Atrea-Integration für Gladys Assistant

Atrea heat recovery ventilation (RD5), local web page: mode, fan power, temperatures, alarms.

Info

Die Dokumentation dieser Integration wird von ihrem Autor geschrieben und ist bisher nur auf Englisch verfügbar.

Shows an Atrea heat recovery ventilation unit with an RD5 regulation (Duplex, ECV…) in Gladys, through the unit's own web page on your local network, without any cloud or account. Unofficial integration, not affiliated with Atrea. Never tested with a real device: Atrea publishes no documentation of this web interface; the integration reads and writes the pages and registers that the open-source pyatrea library and the HomeAssistant-Atrea integration (Home Assistant) use; please report what you see.

Before you start​

  • The unit must be on your network and its web page must open from a browser (port 80). Give it a fixed IP address in your router.
  • Note the password of the web page (leave the field empty if the page asks for none). The unit accepts only a few signed-in users at once: Gladys keeps a single session and signs in again only when the unit asks for it.
  • The web page is plain HTTP: the sign-in goes over your local network like the one of your browser. Keep the unit on a trusted network.

Installation​

  1. Install the integration from the Gladys store.
  2. Enter the IP address of the unit (port 80 unless you add one) and the password of its web page; save.
  3. Open the Discovery tab and add the unit.

What you get​

One device, Atrea ventilation, with:

FeatureNotes
Outdoor, supply, extract, exhaust, indoor, average outdoor temperature°C
Temperature asked°C, read only
Fan power asked%, 12 to 100, a command (see below)
Current fan power%, read only
Ventilation modelist: automatic, ventilation, circulation and ventilation, circulation, night precooling, disbalance, overpressure
Current modetext: off, automatic, ventilation, circulation-ventilation, circulation, night-precooling, disbalance, overpressure, periodic-ventilation, startup, rundown, defrosting, external, hp-defrosting, in1, in2, d1, d2, d3, d4
Control programtext: manual, weekly, temporary
Unit running1 = running; 0 = off or stopping (rundown)
Heating, cooling, filters to changeread only, 1 = yes
Active alerts, active warnings, alarm codescounts; text none or the codes of the unit (D11180, D11183)
Stop the unitbutton

A value outside its range, empty or not a number is never published: Gladys keeps the last known value. The alert and warning lists come from a second page of the unit, read once an hour: when it fails, the other values are published anyway and the alarm features stay unknown until it is read. The air flows (m³/h) and the bypass are not published.

The unit is read every 60 s (30 s to 1 h). The test button, a Discovery scan, a reconnection of Gladys or a restart of the integration never read it sooner than the interval. Reads outside the interval:

  • every command reads the unit right before writing, then reads it back;
  • "Stop the unit" and its resends;
  • 5 s then 20 s after a command or a stop not confirmed, or after a stop that follows a command not confirmed;
  • a new address saved is read at once.

The password​

The password is kept by Gladys in its database, never shown again, sent only to the unit. It is never written in the logs nor in the integration's files. When the unit answers "denied" (wrong password, or too many users signed in to the unit), the next read tries once more; a second refusal in a row stops every sign-in: the status says so, until you save the configuration (the same password counts: one more try) or press Test the connection (one try per press). After a restart, the integration remembers that this password was refused (as a short fingerprint that cannot give the password back), so it does not try it again on its own.

Commands​

The mode and the fan power are refused unless Allow the commands is on (off by default). No switch: a voice assistant's "turn everything off" never reaches the ventilation.

  • Every command reads the unit right before writing (mode, program, fan power, the modes the unit lets be chosen, unit ID), writes nothing when the value already is right, and is confirmed only when the unit reads the value asked back. A read back still showing the state before answers "not applied yet"; a command that may have reached the unit without being confirmed answers "sent, without confirmation": check the unit a few seconds later. A command that cannot be sent within 3.5 s is refused and nothing is sent.
  • Under the weekly program, a change makes the program temporary, as the unit's web page does.
  • Refused: a mode the unit does not let be chosen (its list of writable modes, read each time), when the unit ID read differs from the one learnt or cannot be read (see below), when /data cannot be read or written, when the state of the unit cannot be read just before, when no session can be opened (no password, or refused).
  • A mode starts a unit that is off: with the option on, choosing a mode is how the unit is started again from Gladys. It lifts a stop sent from Gladys (see below).
  • The fan power is a whole number from 12 to 100 %; it is refused on a unit that is off or stopping, and while a stop sent from Gladys is kept: choose a mode first.

Stop the unit​

"Stop the unit" sets the manual program and the mode off (the weekly program would start the unit again). It does not depend on the option, on another command (a command not written yet is cancelled), on a read in progress or stuck (it is interrupted), on a failed read or a wait between two tries, on the unit ID, on /data, nor on the configuration not read again from Gladys yet or made invalid since (it then goes to the address of the kept stop, else the last valid one kept in /data). It is tried again for 3.5 s after the press; an answer to the stop that stops coming for 1 s is cut and the stop sent again. When the session expired, it signs in once per press (the sign-in may take the whole 3.5 s: each sign-in takes a place on the unit). It is confirmed when the unit reads the mode off (or stopping) and the manual program; a unit read off but still in another program is never taken as stopped: the stop is sent again (three sends at most).

It can fail in these cases only, and the answer says so:

  • no address known (never a valid one configured): "not sent";
  • the unit asks for a session and no password can be tried (none saved, refused twice, or the stop goes to another address than the configured one): "not sent", kept, and sent first as soon as a password is saved or the test button succeeds;
  • the session expired and the sign-in of the press failed (no answer in time, connection closed, unreadable answer; a sign-in that could not even connect is tried again within the 3.5 s; one that left is never sent twice in a press: it takes a place on the unit): "not sent", kept, sent first at the next read;
  • the unit refuses the password: "not sent", kept, sent first at the next read;
  • the unit cannot be reached within 3.5 s: "not sent" (or "not sent yet" while it still tries), kept, sent first at the next read;
  • no answer, an error answer, or the unit read back still running: "sent, without confirmation".

The stop is then kept (in /data, with the address). A stop that never reached the unit is never given up: it is sent first at every read until it leaves (while no password can be tried, it waits for a new password or a successful test); only a send that actually left counts as a try. The kept stop is never lifted by the time, only by a mode chosen from Gladys (with the option), or when the unit is read running twice in a row after it was seen off (started from its panel). While it is kept, a read that finds the unit running before it was seen off (or after a command that could still land) sends the stop again, three sends at most; the status says so. A stop that may not have landed when the integration stopped is sent again when it restarts, before the configuration is read again when the unit asks for no password, else right after it.

Identity of the unit​

The device is tied to the unit ID the unit gives (registers H12300 to H12309), learnt at the first read; the ID is read up to its first empty register, trailing blanks removed (blanks inside are kept, shown as "-" in the device id); a unit that gives none (registers missing or empty) is the device "unit". When another ID is read at the address, another unit may answer there: its values are not written into the old device, and the mode and the fan power are refused until Test the connection accepts it; it then becomes a new device in Discovery (the stop never depends on it). An ID that cannot be read is never taken for another unit, but the commands are refused.

What the integration does not do​

It never updates the firmware, never changes the settings (but the program: see the stop and the weekly program above), the schedules or the temperature asked, never resets the alarms nor acknowledges the filters, never reads the translations of the web page.

Konfigurationseinstellungen​

Diese Einstellungen fragt Atrea in seinem Konfigurationsbildschirm in Gladys ab.

EinstellungTypPflichtfeldBeschreibung
Your Atrea unitsectionNeinShows your Atrea heat recovery ventilation with an RD5 regulation (Duplex, ECV…) in Gladys through its own web page on your local network, without any cloud: current mode, program, fan power asked and current, outdoor, supply, extract, exhaust and indoor temperatures, heating and cooling, filters to change, warnings and alerts. Enter the address of the unit (give it a fixed address in your router) and the password of its web page, save, then add the unit from the Discovery tab. The mode and the fan power can be changed from Gladys only if you allow the commands below; "Stop the unit" never depends on that option (see the guide). Gladys never touches the firmware nor the settings. Never tested with a real device. Not affiliated with Atrea.
IP address of the unitstringJaThe address you type to open the web page of the unit: an IPv4 address or a host name (port 80 unless you add one, for example 192.168.0.70:8080).
Password of the web pagesecretNeinThe password you type on the web page of the unit (leave empty if it asks for none). Kept by Gladys in its database, never shown again, sent only to the unit, over plain HTTP like its own web page.
Allow the commandsbooleanNeinOff by default. On: Gladys may change the mode (among those the unit lets be chosen; a mode starts a unit that is off) and the fan power (12 to 100 %, refused on a unit off or stopping). Off: these commands are refused. "Stop the unit" never depends on this option.
Refresh interval (s)numberNeinHow often the unit is read, in seconds.
Language of the feature namesselectNeinUsed for the names of the device and features added from now on, the status and the command errors.

So installierst du Atrea in Gladys​

  1. Öffne in Gladys Integrationen: Atrea erscheint im Katalog neben den nativen Integrationen, mit einem Community-Badge.
  2. Klicke auf Installieren. Gladys lädt das Docker-Image (ghcr.io/lm1lc3n7/gladys-atrea:0.1.1) herunter, startet es in einer vom Kern isolierten Sandbox und erzeugt die Oberfläche der Integration (Geräte, Erkennung und Konfiguration).
  3. Öffne den Bildschirm Konfiguration der Integration, fülle die Einstellungen aus und speichere.
  4. Du kannst sie auch direkt über die URL ihres Repositorys installieren: https://github.com/LM1LC3N7/gladys-atrea.

Atrea benötigt Gladys >=5.1.0. Der Katalog in Gladys wird stündlich aktualisiert, eine neue Version ist also spätestens eine Stunde nach ihrer Veröffentlichung verfügbar.

Du nutzt Gladys noch nicht? Es ist kostenlos und Open Source: folge der Installationsanleitung, um loszulegen.

Über externe Integrationen​

Atrea ist eine externe Integration: eine Community-Integration, die als Docker-Container verpackt und auf GitHub veröffentlicht wird. Gladys installiert sie mit einem Klick und führt sie in einer vom Kern isolierten Sandbox aus. Sie wird von LM1LC3N7 veröffentlicht und gepflegt, nicht vom Gladys-Kernteam.

Abonniere den Newsletter von Gladys Assistant